Winterizing
Winterizing
Time is coming to winterize the unit. I have done Trailers and bigger motor homes but they all had bypass valves at the hot water tank. In my 1997 B-Van I cannot find these.
Does this mean I have to pour about 7 gal. of RV-Antifreese into the system to be sure everything is filled ?
Air7111
Does this mean I have to pour about 7 gal. of RV-Antifreese into the system to be sure everything is filled ?
Air7111
Re: Winterizing
No.
Drain the hot water tank by removing the white plastic drain plug. Drain the water storage tank under the sink by opening the valve under the rear side door. Open the faucet first to let air in. I then drive around a little to let more water slosh out. Sometimes I never use anit freeze, but usually put some in the holding tank and a little down the sink, in case there is a trap.
Drain the hot water tank by removing the white plastic drain plug. Drain the water storage tank under the sink by opening the valve under the rear side door. Open the faucet first to let air in. I then drive around a little to let more water slosh out. Sometimes I never use anit freeze, but usually put some in the holding tank and a little down the sink, in case there is a trap.
- skater
- Site Admin
- Posts: 2571
- Joined: Thu Mar 08, 2007 1:00 am
- B190 Year: 1991
- WBCCI: 13270
- Location: Annapolis, MD
Re: Winterizing
If you're going to use the antifreeze, then you'll need 7 gallons or so. I gave up on the antifreeze because of that, and went to just blowing out the lines using air pressure. That may be sufficient depending on where you are.
1991 Airstream B190 - bought, 2005; sold, 2011; bought 2017
1995 Airstream Excella 30' trailer
WBCCI #13270, Washington, DC Unit
1995 Airstream Excella 30' trailer
WBCCI #13270, Washington, DC Unit
-
- Seasoned Traveler
- Posts: 116
- Joined: Thu Jun 28, 2012 10:14 am
- B190 Year: 1994
- WBCCI: 0
- Location: Silver Creek, MN
Re: Winterizing
I had planned doing a combination of both.
Draining water heater, blowing everything out, adding enough AF to get some into the water heater, and then shutting the bypass valve, as I do have one on my 94. Then add some AF down the drains, and toilet. I was thinking about three gallons total would do it.
I live in far too cold a climate to not use AF.
Draining water heater, blowing everything out, adding enough AF to get some into the water heater, and then shutting the bypass valve, as I do have one on my 94. Then add some AF down the drains, and toilet. I was thinking about three gallons total would do it.
I live in far too cold a climate to not use AF.
Just get on the Bus!!
Mike & Barbara
Mike & Barbara
-
- Newbie
- Posts: 9
- Joined: Sun Sep 09, 2012 9:14 pm
- B190 Year: 1995
- WBCCI: 0
- Location: Mark Twain National Forest, Missouri
Re: Winterizing
Would someone explain, please ... I am a little, no very, confused as to where this 'bypass valve' is, and what it does, concerning the hot water heater. I have yet to deal with any of these appliances, Thanks.
- skater
- Site Admin
- Posts: 2571
- Joined: Thu Mar 08, 2007 1:00 am
- B190 Year: 1991
- WBCCI: 13270
- Location: Annapolis, MD
Re: Winterizing
Using anti-freeze (safe to drink variety, not the kind in car engines) fills the water system and prevents it from freezing down to pretty low temperatures. But, the problem is that you basically have to fill the water heater with it, too, unless the heater has a bypass installed, which allows you to use much less anti-freeze. My '91 didn't have the bypass, so I had to buy ~7 gallons of antifreeze to get the system filled, because the water heater used so much.Minnie wrote:Would someone explain, please ... I am a little, no very, confused as to where this 'bypass valve' is, and what it does, concerning the hot water heater. I have yet to deal with any of these appliances, Thanks.
You can tell by looking at the back of the water heater - if you have the bypass, there will be three valves, and a pipe connecting the water heater inlet to the outlet. Basically you close two of the valves, which closes off the water heater, and open the one on the connecting pipe to allow the anti-freeze to flow through the rest of the system.
Wakeslayer: The manual for my current water heater (which I believe is the same model as what was in my B190) states that it's safe to just drain it; any hard freeze of the remaining water won't be enough to damage the water heater.
1991 Airstream B190 - bought, 2005; sold, 2011; bought 2017
1995 Airstream Excella 30' trailer
WBCCI #13270, Washington, DC Unit
1995 Airstream Excella 30' trailer
WBCCI #13270, Washington, DC Unit
Re: Winterizing
Thanks for all your input. So there is no bypass valve. And for safety reasons I think I will go with my 7 gallons of RV antifreeze.
Happy RVing.
Air7111
Happy RVing.
Air7111
Re: Winterizing
What do all of you do to the fresh water intake valve (hose connection on the left rear)? Do any of you put RV antifreeze in to the hose fitting for winter? Do you blow it out?
- skater
- Site Admin
- Posts: 2571
- Joined: Thu Mar 08, 2007 1:00 am
- B190 Year: 1991
- WBCCI: 13270
- Location: Annapolis, MD
Re: Winterizing
You have to do one or the other (or both). Otherwise you'll have water trapped in there that will freeze. I used a hand pump that had a hose fitting on the end to pump the antifreeze in there.garydi wrote:What do all of you do to the fresh water intake valve (hose connection on the left rear)? Do any of you put RV antifreeze in to the hose fitting for winter? Do you blow it out?
1991 Airstream B190 - bought, 2005; sold, 2011; bought 2017
1995 Airstream Excella 30' trailer
WBCCI #13270, Washington, DC Unit
1995 Airstream Excella 30' trailer
WBCCI #13270, Washington, DC Unit
Re: Winterizing
Thanks Skater. I'm just trying to figure out how to get air pressure in that area. Just bought a short hose to cut up and screw to the hose outlet and my air pump.
-
- Seasoned Traveler
- Posts: 116
- Joined: Thu Jun 28, 2012 10:14 am
- B190 Year: 1994
- WBCCI: 0
- Location: Silver Creek, MN
Re: Winterizing
These are awesome. Just got this for the bus. I bought a crappier version of this from an RV store for my water system at our cabin. Definitely like this actual schrader valve better.
Camco Blowout cap
Camco Blowout cap
Just get on the Bus!!
Mike & Barbara
Mike & Barbara
- skater
- Site Admin
- Posts: 2571
- Joined: Thu Mar 08, 2007 1:00 am
- B190 Year: 1991
- WBCCI: 13270
- Location: Annapolis, MD
Re: Winterizing
I have one of those that has a metal valve stem. I also have one of these, which work if you have an air compressor with a hose with quick connections.Wakeslayer wrote:These are awesome. Just got this for the bus. I bought a crappier version of this from an RV store for my water system at our cabin. Definitely like this actual schrader valve better.
Camco Blowout cap
1991 Airstream B190 - bought, 2005; sold, 2011; bought 2017
1995 Airstream Excella 30' trailer
WBCCI #13270, Washington, DC Unit
1995 Airstream Excella 30' trailer
WBCCI #13270, Washington, DC Unit
-
- Weekend Camper
- Posts: 65
- Joined: Tue Jan 24, 2012 12:07 pm
- B190 Year: 1992
- WBCCI: 0
- Location: New Jersey
Re: Winterizing
Does anyone have any pics of the white plastic drain plug for the hot water heater? i havent been able to find mine.
- skater
- Site Admin
- Posts: 2571
- Joined: Thu Mar 08, 2007 1:00 am
- B190 Year: 1991
- WBCCI: 13270
- Location: Annapolis, MD
Re: Winterizing
Like this? I'm not sure if that's what you mean or not.Eamonn McG wrote:Does anyone have any pics of the white plastic drain plug for the hot water heater? i havent been able to find mine.
1991 Airstream B190 - bought, 2005; sold, 2011; bought 2017
1995 Airstream Excella 30' trailer
WBCCI #13270, Washington, DC Unit
1995 Airstream Excella 30' trailer
WBCCI #13270, Washington, DC Unit
Re: Winterizing
I also can't find my white plastic drain cap -instead I have a metal pipe - which seems to just leak any water i put into the tank -
How do I fit a hot water cut off valve? IN the back under the closet? - is it just a matter of putting shut off valves on each of the water pipes going to my tank?
thanks
Mark
How do I fit a hot water cut off valve? IN the back under the closet? - is it just a matter of putting shut off valves on each of the water pipes going to my tank?
thanks
Mark